TROUBLE SHOOTING - OIL FILTERING PROBLEMS
PROBLEM POSSIBLE CAUSE SOLUTION
FILTER PUMP wont POWER SWITCH not in Press POWER SWITCH to
run FILTER position FILTER position
PUMP MOTOR OVERLOAD Allow motor to cool, then
tripped press red RESET button on
back of PUMP MOTOR
Defective FILTER SWITCH Replace SWITCH
Defective POWER SWITCH Replace SWITCH
PUMP will not pump SUCTION TUBE not seated in Make sure FILTER RESER-
cooking oil SUCTION RECEPTACLE VOIR is properly installed
SUCTION TUBE O-RING Replace O-RING with one of
missing or damaged the three spares
Damaged SUCTION TUBE Replace damaged
or SUCTION RECEPTACLE components
PUMP CHECK VALVE plugged Clean CHECK VALVE
or reversed Install CHECK VALVE properly
FILTER PAPER clogged Scrape crumbs and other
debris from FILTER PAPER
Service FILTER RESERVOIR
at next opportunity
FILTER SCREEN not installed Properly install SCREEN
or improperly installed
PUMP pumps lots of SUCTION TUBE not seated in Make sure FILTER RESER-
bubbles in cooking oil SUCTION RECEPTACLE VOIR is properly installed
SUCTION TUBE O-RING Replace O-RING
missing or damaged
Insufficient oil entering or in Incrementally open DRAIN
FILTER RESERVOIR VALVE and/or clear crumbs
and other debris from DRAIN
PUMP MOTOR tripped PUMP jammed with debris Unjam PUMP
wont reset Defective PUMP HEAD Replace PUMP HEAD
Defective PUMP MOTOR Replace MOTOR only
Oil is not being fltered FILTER PAPER missing, Properly install FILTER
completely damaged or mis-installed PAPER