GENERAL SPECIFICATIONS
1
DIMENSIONS
Wide 15.70”
Deep 33.25”
High 40.0”
ELECTRICAL
Voltage Requirement 208 VAC
240 VAC
380-415 VAC (Export)
Note: Shipped from the factory 3 phase, field convertible to single phase
Power Consumption 9,000 Watts
(Europe) 9,300 Watts
Amperage
208V 1∅ 43.3 Amp
240V 1∅ 37.5 Amp
208V 3∅ 25.0 Amp per leg
240V 3∅ 21.7 Amp per leg
NOTICE: For 208/240V supply connections use 12 ga. copper wire suitable for
at least 75º Centigrade.
380-415V 3∅ L1 14.3 Amp, L2 & L3 13.0 Amp
See European Operations Manual p/n 301796AS for 380-425V supply wiring
connection requirements.