LOWER CONTROL BOX
(Located behind Lower Control Panel)
1. TERMINAL BLOCK: Used to connect power source
wires to Fryer. (Behind Terminal Block Cover [J] ).
2. HI - LIMIT CONTACTOR: Energized any time
POWER SWITCH is in the FRYER position and the
HI-LIMIT THERMOSTAT is within its normal range.
3. GROUND LUG: To connect the building EARTH
GROUND wire to equipment (Fryer) CHASSIS
GROUND. (Behind Terminal Block Cover [J] ).
4. BUSHING, HI - LIMIT: Seals the HI-LIMIT
THERMOSTAT capillary tube to the frypot.
5. HEATING ELEMENT: Heats the cooking oil. The
heating element is turned ON and OFF by the
TEMPERATURE CONTROL THERMOSTAT.
6. BUSHING, TEMPERATURE CONTROL: Seals the TEMPERATURE CONTROL THERMOSTAT capillary
tube to the frypot.
FIELD WIRING INSTALLATION AND INSPECTION INSTRUCTIONS
18
CAUTION: Exposed electrical circuits
Disconnect electrical power before opening the TERMINAL
BLOCK COVER [J], or the CONTROL BOX COVER [N].
1. Remove TERMINAL BLOCK COVER marked REMOVE THIS COVER FOR TERMINAL BLOCK.
2. Supply wires must be attached to the TERMINAL BLOCK terminals marked L1, L2, and L3.
Green GROUND wire must be attached to the GROUND LUG marked “ ”.
3. Use a 90º conduit fitting/strain relief of the appropriate size. Secure the fitting to the rear of the LOWER
CONTROL BOX using the provided knockout. The fitting must angle DOWN.
4. Supply wires must be routed and secured away from the FRYPOT, FILTER MOTOR and tubing/plumbing.