Wells WFAE-30F Specifications Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
WIRING DIAGRAM
20
M381 2M-301603 Owners Manual (Supplemental) NFPA Hood
X
2M-Z13152-3~
WVAE-55FS & VAE-55FS
3Ø, 208V OR 240V, 17KW
S
S
17
414242
240
47
4848
L3
L2L1
AMPS
FRYER RATING
VOLTS
208
RED
18
BLD'G ALARM RELAY
(2&4) BEHIND REAR
BOTTOM COVER ON
RIGHT HAND SIDE OF
BOTTOM PANEL.
NO
COM
NC
3
4
2
5
1
NOT UL LISTED
ON SINGLE PHASE
BOTTOM
TOP
50VA X-FORMER
8500W ELEMENT
8500W ELEMENT
*
*
*
58
58
220V 60HZ
BUZZER
WHITE
RED
THERMO-
COUPLE
24V
208V
240V
13
12
S
30
16
16
18
17
22
31
31
20
16
25
40
WHITE
19
33
32
-
+
CONTROLLER
EXTERNAL INTERLOCK
TERMINAL BLOCK
(REMOVE JUMPER
WHEN EXTERNAL
CONTROL IS USED)
AUDIBLE
ALARM
NOTE: -WIRE NUMBERS 16, 17 AND 18 ARE ROUTED THRU
A 3/8 INCH FLEXIBLE CONDUIT.
-WIRE NUMBERS 26, 27, AND 36 ARE ROUTED THRU
A 3/8 INCH FLEXIBLE CONDUIT.
TWO MAGNET SWITCHES LOCATED BEHIND TOP REAR PANEL.
CONTROLLER
TRANSFORMER
GREEN
GREEN
34
27
26
27
26
50-60 HZ
FILTER
PUMP
MAIN
TERMINAL
BLOCK
E-SAFE
RELAY
1L1
1L2
1L3
1L1
1L2
1L3
SAFETY
CONTACTOR
1
2
3
1
2
3
1
2
3
6
5
4
15
C
POWER
SWITCH
9
9
14
15
BASKET LIFT
ACTUATOR
LIMIT SWITCHES
INSIDE MTR HSG
BLACK
7
8
+
-
SOLID STATE
RELAY
1
2
4
3
-
+
SOLID STATE
RELAY
1
2
4
3
-
+
57
BAFFLE FILTER
MAGNET OPERATED
SWITCH
HEPA FILTER
MAGNET OPERATED
SWITCH
WIRE
NUT(2)
41
42
BROWN
56
BLACK
RED
1/4 INS
FEMALE
1/4 INS
MALE
40
54
41
52
44
44
45
M
1/4 INS
FEMALE(2)
VENTILATOR
POWER
LIGHT
(GREEN)
53
CHECK
FILTER
LIGHT
(AMBER)
REPLACE
FILTER
LIGHT
(AMBER)
SERVICE
REQUIRED
LIGHT
(RED)
NC
C
2
1
3
NO
C
1/4 INS
MALE
1/4 INS
FEMALE
AIR FLOW
VACUUM
SWITCH
(LARGE)
BLOWER
MOTOR
REPLACE
FILTER
VACUUM
SWITCH
(SMALL)
INTERVAL TIMER
50
44
45
46
47
48
49
56
55
44
41
51 51
HOOD
HOOD
UPPER CONTROL BOX
UPPER CONTROL BOX
1/4 INS
MALE(2)
42
43
30
30
10
21
22
10
23
21
11
123
6 5 4
789
101112
9 6 3
8 5 2
147
6
5
4
3
2
1
24V
24 V PLUMBING
HEATER TAPE
24 V FILTER PAN
HEATER PAD
S
SPARK
QUENCHER
(SNUBBER)
OPTIONAL SOLID
SHORTENING MELT
OPTION
(BASKET DOWN)
(BASKET UP)
AC
AC
DC
DC
DOWN
UP
UP
-
+
COM
(DN)
(UP)
(COM)
S
59
59
M-S
FUSE
15A MAX
FUSE
15A MAX
L3
L2
L1
JUMPER
43
HI LIMIT
THERMOSTAT
23
14
8A
S
38
37
X
Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454
2940 Hwy 14 W, Rochester, MN 55901
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 31 32

Comments to this Manuals

No comments