M381 2M-301603 Owners Manual (Supplemental) NFPA Hood
15
TROUBLESHOOTING SUGGESTIONS
NOTE:
FILTERS are the only user serviceable components
in this ventilator hood system. For all problems that
cannot be remedied by servicing the lters, contact:
Fryer or ventilator section - authorized Wells ser-
vice agency
Fire suppression system - authorized Ansul®
distributor
IMPORTANT:
Contact ANSUL® for re suppression system installation, set-up and service:
Ansul Incorporated 1-800-TO-ANSUL (1-800-862-6785)
One Station Street
Marinette, WI 54143-2542 website http;//www.ansul.com
IMPORTANT:
Parts used in the Ansul® re suppression system are not serviceable by the owner/operator.
Procedures for servicing re suppression equipment are described in:
ANSUL® R-102 SYSTEM DESIGN, INSTALLATION, RECHARGE AND MAINTENANCE MANUAL
(418087, current edition)
NOTE:
ANSUL® Manual 41807 and Wells Bulletin 301646 are intended for use by authorized Ansul® service
personnel only.
Problem Possible Cause Suggested Remedy
Unit will not operate
Disconnected from electric power
Reconnect to electric power
(no indicators lights lit) Reset circuit breaker for unit
Unit will not operate
Fire suppression system not set Contact an authorized Ansul® distributor for repairs
(buzzer sounds)
CHECK FILTER light lit HEPA air lter or grease bafe not in position Properly install HEPA lter and grease bafe
REPLACE FILTERS light lit
HEPA air lter and charcoal lters nearing end of service
life
Arrange to replace both HEPA and charcoal lters in a
timely manner
SERVICE REQUIRED light lit HEPA air lter and charcoal lters plugged Replace both HEPA and charcoal lters
(fryer not operating) Fire damper in exhaust collar has closed Contact an authorized Wells service agent for repairs
One or more vacuum sensing lines or ports plugged Contact an authorized Wells service agent for repairs
NOTE: If, after 10 seconds, there is insufcient airow for proper operation, SERVICE REQUIRED light will illuminate
and fryer will be de-energized.
Press FRYER POWER SWITCH to OFF, then back to FRYER to reset system.