PRINTED IN UNITED STATES OF AMERICAWELLS BLOOMFIELD, LLC2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439www.wellsbloomfield.comtelephone: 775-689-5703fax:
OPERATION NOTES 1. Never place food directly in cold pans. Always use insets or food pans. 2. Use only pre-chilled products. Stir product occasi
CLEANING INSTRUCTIONS 9 CAUTION: ELECTRIC SHOCK HAZARD DO NOT splash or pour water onto control panel or wiring. IMPORTANT: DO NOT use steel woo
10 CONDENSER COIL CLEANING INSTRUCTIONS The condenser coil must be kept clean to allow adequate air flow for proper heat dissipation. Recommend this
11 CAUTION: PERSONAL INJURY HAZARD Disconnect appliance from electrical power before cleaning. Wells refrigerated cold pans are constructed of high
12 MAINTENANCE INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT RCP-100 thru RCP-600 1. The temperature has been preset at the factory to meet most
13 MAINTENANCE INSTRUCTIONS (continued) IMPORTANT: DO NOT adjust the differential settings of the refrigeration system. Field adjustments of the diff
14 TROUBLESHOOTING SUGGESTIONS 405 p/n 305101 OpM RCP Refrigerated Cold Pans
DESCRIPTION PART NO. DRAIN SCREEN 21709 SOUP LADEL, 6 oz. 21764 ADAPTER BAR FOR 12" X 20" PANS 22016 P
Genuine PartsProtect - YOU - All - WaysSERVICE TRAINING - QUALITY SERVICESERVICE TRAINING - QUALITY SERVICECUSTOMER SATISFACTIONCUSTOMER SATISFACTIONW
405 p/n 305101 OpM RCP Refrigerated Cold Pans All commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects i
WARRANTY xi SPECIFICATIONS FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY L
FEATURES & OPERATING CONTROLS 2 NOTE: This is a general arrangement drawing only. Actual component positions may vary between units. 405 p/n 30
3 This appliance is intended for use in commercial establishments only, and is intended to hold pre-chilled prepared food for human consumption. No
4 AGENCY LISTING INFORMATION 405 p/n 305101 OpM RCP Refrigerated Cold Pans This appliance is performance tested to NSF Standard 4 for holding hot foo
INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for pr
6 WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated elec-trical components must be performed by a factory au-thorized
7 IMPORTANT: Plumbing connections must be made in compliance with all Federal, State and Local Codes and Ordinances. IMPORTANT: All drain plumbing in