SERVICING INSTRUCTIONS
5
CAUTION:
ELECTRIC SHOCK
HAZARD
Unplug appliance from
electric power before
removing any panel or
access cover.
3
4
5
6
7
1
2
3032730327
SOLID CONDUIT
P/N 55547
CONDUIT, CAST
P/N 50329
Insert small diameter end
into hinge
HINGE PLUG
P/N 50328
HINGE
P/N 50322
SCREW 8-32
P/N 51715 (pk 100)
Pull ground wire up to center
Ground wire gets 4“ of
FIBERGLASS SLEEVE
P/N 54573 (rl 100ft)
after it is pulled into casting
Pull power wires up
above casting numbers
Power wires get 9“ of
RUBBERIZED SLEEVE
P/N 50284 (rl 10 ft)
Ground wire
CASTING AND HINGE ASSEMBLY
CASTING, TOP
P/N 50327
8
GRID, TOP P/N 50454
GASKET, GRID P/N 50337
Check to insure gasket is
installed flush around casting
9
12
10
11
CLAMP PLATE, TOP
P/N 50431
INSULATION PAD,
WB ELEMENT TOP
P/N 50430
ELEMENT,
120V 450W P/N 50450
Check for correct voltage
and wattage.
Assemble so that terminals
will be on side of hinge with
solid conduit.
SCREW, 8-32 x 5/16“ P/N 51715 (pk 100)
Do not tighten until all screws are in place.
Ensure that element terminals are centered
in opening before tightening.
Trap ground wire under this screw.
Insert stud on clamping plate of Grid & Element Assembly
into hole in top casting of Casting & Hinge Assembly.
Ensure that gasket is evenly seated, then secure assemblies
with TenzNut (RING, RETAINING P/N 50222 pk 10).
Insert PLUG, TOP CASTING P/N 58628
NOTE: Washer
GRID & ELEMENT ASSEMBLY
13
14
A. TOP GRID ASSEMBLY
212 5029732 SvcManual for WB-1, -2 Waffle Bakers