Page view 6
ITEM
F.01
F.02
F.04
F.05
F.06
F.07
F.08
W.01
W.02
W.03
W.04
W.05
W.06
W.07
W.08
W.09
DESCRIPTION
POWER SWITCH
TIMER
TEMPERATURE CONTROL
THERMOSTAT
HEAT INDICATOR
TROUBLE INDICATOR
HI-LIMIT RESET
DRAIN VALVE
WARMER TEMPERATURE
CONTROL
POWER ON INDICATOR
THERMOMETER (optional)
HUMIDITY CONTROL
DRAWER CATCH
DRAWER STOP
DRAWER ROLLERS
POWER SWITCH (RWT)
CONTROLLER (RWT)
COMMENT
Turns fryer section
ON or OFF.
Set to desired time, press to lower basket and begin timed cook cycle.
Set to desired cooking temperature.
AMBER. Glows when heating element is energized.
RED. Glows if safety thermostat is tripped.
Allows hi-limit safety thermostat to be reset after oil has cooled below
400ºF.
Optional frypot drain. Valve is 1/4-turn ball valve.
NOTE: Drain not available on RW (roll warmer ) units
Infinite switch control of temperature of one warmer drawer.
AMBER. Glows when associated temperature control is turned ON.
Reads temperature inside drawer cavity
Must be ordered at time of initial build.
Slide control of shutters to control air circulation within the warmer
drawer.
Holds drawer closed.
Prevents drawer from opening too far. Spring loaded to permit easy
removal of drawer.
Support drawer and allow it to open and close smoothly.
Energizes unit (RWT-style only)
Controls cavity temperature. Readout displays setpoint and actual
temperature information. UP ARROW / DOWN ARROW keys allow
modification of setpoint temperature. (RWT-style units only)
FEATURES & OPERATING CONTROLS (continued)
FRYER SECTION CONTROLS
OPTIONAL WARMER SECTION CONTROLS
5