  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
AGENCY LISTING INFORMATION
INSTALLATION
4
NOTE: DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation.
Refer to SHIPPING DAMAGE
CLAIM PROCEDURE on the
inside front cover of this
manual.
IMPORTANT: This is a
GENERAL GUIDE. For
specic equipment and
cutout dimensions, and other
installation details, refer to
the Installation Instructions
supplied with the appliance.
IMPORTANT: Water damage
caused by failure to set
Wellsloks, failure to install
gasket, or failure to seal ange
to counter is NOT covered by
warranty.
UNPACkING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective
plastic lm, packing materials and accessories from the appliance
before connecting electrical power or otherwise performing any
installation procedure.
Carefully read all instructions in this manual and the Installation
Instruction Sheet packed with the appliance before starting any
installation.
Read and understand all attached labels and diagrams.
Carefully account for all components and accessories before discarding
packing materials. Store all accessories in a convenient place for later
use.
CUT-OUT AND INSTALLATION
Cutouts
Griddles may be installed in METAL COUNTERS ONLY.
Cutout dimensions for griddles and control panels are listed on
the Installation Instructions provided with the griddle.
Refer to the Installation Instructions for Underwriters
Laboratories Conditions of Acceptability.
Mounting the griddle:
Verify that provided sealants are applied to the under side of
the griddle top ange prior to setting the unit into the cutout.
After installation, verify that the tabs on the Wellsloks are
turned out to lock the appliance into the counter (see Fig. 2).
Apply a thin bead of food-grade silicone sealant around the
ange to seal it to the counter.
Refer to the Installation Instructions for required clearances. Maintain
required clearances between the appliance and adjacent combustible
and non-combustible surfaces.
Sufcient overhead clearance must be provided to allow the element
assembly to be raised. Refer to the Installation Instruction Sheet for
required clearances.
Avoid storing ammable or combustible materials near the appliance.
This includes gasoline and other fuels, mops, rags and wrapping paper.
a.
b.
c.
a.
b.
c.
Fig. 2 Set the Wellslloks
This appliance conforms to NSF Standard 4 for sanitation only if
installed in accordance with the supplied Installation Instructions.
This appliance is Underwriters Laboratory recognized ( ). Since this
appliance is only a single component of a complete installation, the
nished installation of this unit requires additional evaluations to
Underwriters Laboratory standards.
Refer to Installation Instructions included with the appliance for
Underwriters Laboratories conditions of acceptability, electrical
requirements and other installation concerns.