Wells WG-3036G Specifications

Browse online or download Specifications for Electric griddles Wells WG-3036G. Wells WG-3036G Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WELLS MANUFACTURING
10 Sunnen Dr., St. Louis, MO 63143
telephone: 314-678-6314
fax: 314-781-2714
www.wellsbloomfield.com
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
121
p/n 2M-45324 Rev. F M225 130123
OWNERS MANUAL
COUNTERTOP
GAS
GRIDDLES
MODELS
WG2424G
WG2436G
WG3036G
WG3048G
Model WG2424G
FOR YOUR SAFETY
Do not store gasoline or other ammable liquids
in the vicinity of this or any other appliance.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this equipment.
IMPORTANT:
The purchaser of this equipment must post in a prominent location instructions to be followed in the
event the user smells gas. This information shall be obtained by consulting the local gas supplier.
Includes
INSTALLATION, USE & CARE
EXPLODED VIEW & PARTS LIST
WIRING DIAGRAM
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - WIRING DIAGRAM

WELLS MANUFACTURING10 Sunnen Dr., St. Louis, MO 63143telephone: 314-678-6314fax: 314-781-2714www.wellsbloomfield.comIMPORTANT: DO NOT DISCARD THIS MA

Page 2 - LIMITED WARRANTY STATEMENT

INITIAL ADJUSTMENTIMPORTANT: PRESSURE ADJUSTMENT MUST BE PERFORMED BY A QUALIFIED TECHNICIAN ONLY.IMPORTANT: FLAME ADJUSTMENT MUST BE PERFORMED BY A Q

Page 3 - INTRODUCTION

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesINITIAL ADJUSTMENTPREPARING THE GRIDDLE SURFACESEASONING STANDARD GRIDDLESAs manufactured, th

Page 4

OPERATIONGENERAL OPERATIONAL NOTESCarefully read the description of the griddle operation on the specication sheet.Do NOT use this appliance if it ha

Page 5 - FALL HAZARD

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesWARNING: FIRE AND EXPLOSION HAZARDIf the pilot light should be extinguished, turn off the

Page 6

CAUTION:BURN HAZARD Griddle will be hot during portions of this cleaning procedure. Always heat-protective gloves and apron.IMPORTANT: DO NO

Page 7 - GAS APPLIANCE CODE COMPLIANCE

M121 p/n 2M- 45324 Owners Manual Countertop Gas Griddles13PREPARATION Set temperature control to 220ºF. Allow griddle temperature to drop to 220º

Page 8

TROUBLESHOOTING14M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesDESCRIPTION POSSIBLE PROBLEM SUGGESTED REMEDYPilot will not light Gas sup

Page 9

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesWIRING DIAGRAM15NOTE:Shown is the wiring diagram for a single burner section. Each burner se

Page 10 - LOCKING SCREW

EXPLODED VIEW & PARTS LIST18M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesWG2424G CABINET COMPONENTSModel: WG2424GCountertop Gas Griddl

Page 11 - INITIAL ADJUSTMENT

M121 p/n 2M- 45324 Owners Manual Countertop Gas Griddles19EXPLODED VIEW & PARTS LISTWG2424G FUEL SYSTEM COMPONENTSModel: WG2424GCountertop Gas Gr

Page 12 - LIGHTING INSTRUCTIONS

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesUnless otherwise specied, all commercial cooking equipment manufactured by Wells Manufacturi

Page 13 - WARNING:

PARTS LIST: WG242420M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesModel: WG2424 Gas GriddleFig No. Part Number Quantity Description Applic

Page 14

EXPLODED VIEW & PARTS LIST 21WG2436G CABINET COMPONENTS3 places3 places4 places2 places68528ASSEMBLY5903965951593312C-35485G7-Z183072436PS model2

Page 15 -

22EXPLODED VIEW & PARTS LISTWG2436G FUEL SYSTEM COMPONENTSModel: WG2436GCountertop Gas Griddle: Fuel System ComponentsPL121IL1832 Rev. C 8/30/12

Page 16 - TROUBLESHOOTING

EXPLODED VIEW & PARTS LIST23WG3036G CABINET COMPONENTS3 places3 places2 placesG7-393312C-35485G7-45292G7-452782C-33453WS-59173G7-Z120472R-386682M-

Page 17 - THERMOPILE

24EXPLODED VIEW & PARTS LISTWG3036G FUEL SYSTEM COMPONENTSModel: WG3036GCountertop Gas Griddle: Fuel System ComponentsPL121IL1839 Rev. C 8/30/12

Page 18 - WG2424G CABINET COMPONENTS

EXPLODED VIEW & PARTS LIST25WG3048G CABINET COMPONENTSModel: WG3048GCountertop Gas Griddle: Cabinet ComponentsPL121IL1840 Rev. C 9/02/14Namplate

Page 19 - IL1837 Rev. D 4/13/12

26EXPLODED VIEW & PARTS LISTWG3048G FUEL SYSTEM COMPONENTSModel: WG3048GCountertop Gas Griddle: Fuel System ComponentsPL121IL1841 Rev. C 8/30/12

Page 21 - WG2436G CABINET COMPONENTS

CUSTOMER SERVICE DATAplease have this information available if calling for serviceRESTAURANT _____________________________ LOCATION _____________INS

Page 22 - 2A-45300

WELLS MANUFACTURING10 Sunnen Dr., St. Louis, MO 63143telephone: 314-678-6314fax: 314-781-2714www.wellsbloomfield.comIMPORTANT: NE JETEZ PAS CE MANUELC

Page 23 - WG3036G CABINET COMPONENTS

M121 p/n 2M- 45324 Owners Manual Countertop Gas Griddles1WARRANTY xiSPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2PRECAUTIONS &

Page 24 - IL1839 Rev. C 8/30/12

M121 p/n 2M- 45324 Owners Manual Countertop Gas Griddles1SPÉCIFICATIONS 1CARACTÉRISTIQUES ET COMMANDES DE FONCTIONNEMENT 2PRÉCAUTIONS ET RENSEIG

Page 25 - WG3048G CABINET COMPONENTS

FRENCHFig. 1 Plaque de comptoir à gaz – Caractéristiques et commandes de fonctionnement2M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesCARAC

Page 26 - Model: WG3048G

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesCet appareil est conçu pour la préparation d’aliments destinés à l’alimentation humaine. Cet

Page 27

FRENCHINSTALLATIONREMARQUE: NE PAS jeter la boîte ou tout autre emballage tant que l’appareil n’a pas été inspecté pour y détecter des dommages et mis

Page 28 - CUSTOMER SERVICE DATA

DANGER:RISQUE D’INCENDIE ET D’EXPLOSIONNE JAMAIS utiliser une amme nue pour procéder à la vérication des fuites de gaz. Cela peut entraîner un incen

Page 29 - Modèle WG2424G

FRENCHINSTALLATIONINSTALLATION DE LA PLAQUESe reporter à la plaque signalétique. Vérier le type de comburant et la pression, lesquels doivent corresp

Page 30 - SPÉCIFICATIONS

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesINSTALLATION MISE À L’ESSAI SOUS PRESSION DU CONDUIT À GAZLe système de conduit principal doi

Page 31 - LA GRAISSE

FRENCHRÉGLAGE INITIALIMPORTANT: LE RÉGLAGE DE LA PRESSION DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN QUALIFIÉ UNIQUEMENT.IMPORTANT: LE RÉGLAGE DE LA FLAMME

Page 32 - ATTENTION:

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesRÉGLAGE INITIALPRÉPARATION DE LA SURFACE DE LA PLAQUEHUILAGE DES PLAQUES STANDARDSTel que fab

Page 33 - INSTALLATION

FRENCHFONCTIONNEMENTREMARQUES GÉNÉRALES SUR LE FONCTIONNEMENTLire attentivement la description du fonctionnement de la plaque présente sur le feuillet

Page 34

Fig. 1 Countertop Gas Griddle - Features & Operating Controls2M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesFEATURES & OPERATING C

Page 35 - DANGER:

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesMISE EN GARDE: RISQUE D’INCENDIE ET D’EXPLOSIONSi la veilleuse s’éteint, fermer la soupape d’

Page 36

FRENCHATTENTION: RISQUE DE BRÛLURESLa plaque sera chaude pendant les portions de cette procédure de nettoyage.Toujours porter des gants et un tablier

Page 37 - OBTURATEUR

M121 p/n 2M- 45324 Owners Manual Countertop Gas Griddles13PRÉPARATION Régler la température à 220 °F (104 °C). Laisser la température de la plaque a

Page 38 - RÉGLAGE INITIAL

FRENCHSUGGESTIONS DE DÉPANNAGE14M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesDESCRIPTION PROBLÈME POTENTIEL RÉPARATION SUGGÉRÉELa veill

Page 39

WELLS MANUFACTURING10 Sunnen Dr., St. Louis, MO 63143telephone: 314-678-6314fax: 314-781-2714www.wellsbloomfield.com

Page 40 - FONCTIONNEMENT

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesThis appliance is intended for use in commercial establishments only.This appliance is intend

Page 41

INSTALLATIONNOTE: DO NOT discardthe carton or other packingmaterials until you haveinspected the appliance forhidden damage and tested it for proper

Page 42

DANGER:FIRE ANDEXPLOSIONHAZARDNEVER use an open ame to check for gas leaks. Fire and explosion may result.IMPORTANT:All pipe joints must be checked

Page 43 - SUGGESTIONS DE DÉPANNAGE

INSTALLATIONINSTALLING THE GRIDDLERefer to the nameplate. Verify the fuel type and pressure, which must match the nameplate specications. Connecting

Page 44 - WELLS MANUFACTURING

M121 p/n 2M- 45324 Owners Manual Countertop Gas GriddlesINSTALLATION GAS PIPE PRESSURE TESTINGThe main piping system must be capable of supplying th

Comments to this Manuals

No comments