Wells F-49RT Operations Instructions Page 1

Browse online or download Operations Instructions for Deep fryers Wells F-49RT. Wells F-49RT Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WELLS BLOOMFIELD, LLC
10 Sunnen Dr., St. Louis, MO 63143
telephone: 888-356-5362
fax: 314-781-2714
www.wells-mfg.com
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
363
p/n 2M-300007 Rev. H M361 101221
OWNERS MANUAL
ELECTRIC
OPEN FRYPOT
55# FRYER
with AUTO-LIFT
MODEL
WFAE55F
WVAE55F
(FRYER SECTION ONLY)
WFAE55FS
WVAE55FS
(FRYER SECTION ONLY)
WITH OR WITHOUT
OPTIONAL FILTER WAND
Includes
INSTALLATION
USE & CARE
EXPLODED VIEW
PARTS LIST
WIRING DIAGRAM
WARNING:
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the installation and operating
instructions thoroughly before installing, using or servicing this equipment.
WFAE55F
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - WELLS BLOOMFIELD, LLC

WELLS BLOOMFIELD, LLC10 Sunnen Dr., St. Louis, MO 63143telephone: 888-356-5362fax: 314-781-2714www.wells-mfg.comIMPORTANT: DO NOT DISCARD THIS MANUAL

Page 2 - LIMITED WARRANTY STATEMENT

INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for pr

Page 3 - INTRODUCTION

ELECTRICAL INSTALLATION Refer to the nameplate on the front of the fryer and to the specifications listed on page 1 of this manual. Verify that elec

Page 4 - THERMOSTAT

PREPARATION PRIOR TO OPERATION 10 Press POWER SWITCH OFF. Close DRAIN VALVE (lever horizontal). Fill FRYPOT with 4 gallons of cold water. Press POWE

Page 5 - FIRE HAZARD / HOT OIL

PREPARATION PRIOR TO OPERATION (continued) 11 Press POWER SWITCH OFF. Close DRAIN VALVE (lever horizontal). Fill FRYPOT with 4 gallons of cold water.

Page 6 - HI-LIMIT

PREPARATION PRIOR TO OPERATION (continued) 12 Examine the CRADLE ROLLERS. Adjust or tighten as required. Lubricate the rollers with vegetable oil.

Page 7

PREPARATION PRIOR TO OPERATION (continued) 13 FOR FRYERS WITH VENT HOOD (WVAE-55…..) For Ventilator Hood models (i.e. WVAE-55 FS), install DR

Page 8

PREPARATION PRIOR TO OPERATION (continued) 14 Check operation of FRYER and all CONTROLS. WFAE-55F: See page 15 WFAE-55FS: See page 16

Page 9 - AGENCY LISTING INFORMATION

OPERATION - WFAE-55F (MANUAL CONTROLS) 15 PRE-HEATING FRYER Make sure FRYPOT is filled with 55 LB. of cooking oil. Open door and set THERMOSTAT (ite

Page 10 - FIRE HAZARD

OPERATION - WFAE-55FS (SOLID STATE CONTROLS) 16 PROGRAMMING KEY FUNCTIONS As each control panel key is pressed, a “beep” will sound. Illuminated indi

Page 11

OPERATION - WFAE-55FS (continued) 17 PROGRAM MENU TIMES AND TEMPERATURES For solid shortening melt optioned fryers, make sure elements are packed wi

Page 12 - WARNING:

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer Unless otherwise specified, all commercial cooking equipment manufacture

Page 13

USING FUNCTION KEYS PAUSE Halts time countdown while any menu is running and readout displays time remaining. • Purpose: Allows the user to raise f

Page 14 - LIFT CRADLE

OPERATION - WFAE-55F (MANUAL CONTROLS) 19 PRE-HEAT THE FRYER Press any MENU key. If oil temperature has not reached programmed temper

Page 15 - COLD OIL LINE

OPTIONAL OIL WAND WASH OUT FRYPOT or DISCARD OIL 1. If discarding oil, be sure a suitable hot oil disposal container is available. Other

Page 16

OPTIONAL OIL WAND RETURN FRYER TO NORMAL OPERATION 1. After washing down frypot, turn DRAIN VALVE HANDLE horizontal to close the frypot dra

Page 17 - CAUTION:

CLEANING INSTRUCTIONS 22 122 306626 OpManual for HDG-Series Griddles 122 306626 OpManual for HDG-Series Griddles DANGER: BURN HAZARD Contact w

Page 18

23 CLEANING INSTRUCTIONS (continued) PREPARATION Drain oil from fryer before cleaning FREQUENCY Monthly, or as needed TOOLS Low-foaming commer

Page 19

24 CLEANING INSTRUCTIONS (continued) PREPARATION Drain oil from fryer before cleaning FREQUENCY Monthly, or as needed TOOLS Low-foaming commer

Page 20

MAINTENANCE INSTRUCTIONS - FILTER SYSTEM 25 IMPORTANT: Make sure all oil is pumped into FRYPOT before removing reservoir. NOTE: When properly assemb

Page 21

MAINTENANCE - FILTER SYSTEM (continued) 26 NOTE: Oil should be at least 300ºF (149ºC) DO NOT attempt to filter cold oil. DO NOT attempt to pump oil

Page 22 - BURN HAZARD

MAINTENANCE - FILTER SYSTEM (continued) 27 Carefully and slowly add the contents of one package of FILTER POWDER to the oil in the frypot. Sprinkle f

Page 23

WARRANTY xi SPECIFICATIONS 1 WFAE-55F FEATURES & OPERATING CONTROLS 2 WFAE-55FS FEATURES & OPERATING CONTROLS

Page 24

MAINTENANCE - DISCARDING USED OIL 28 Press POWER SWITCH to OFF. Allow oil to cool to 120ºF (49ºC)or less before attempting to drain oil from fryer.

Page 25

MAINTENANCE - DISCARDING USED OIL (continued) 29 Screw provided 1-1/4 NPT STREET ELBOW into DRAIN VALVE. Position female end to point forward. Screw

Page 26

MAINTENANCE INSTRUCTIONS - CRADLE LIFT 30 NOTE: Failure to keep the cradle lift screw properly lubricated will result in premature wear of the brass

Page 27 - WARNING: BURN HAZARD

TROUBLESHOOTING - WFAE-55F (Manual Controls) 31 SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Fryer will not heat Unit disconnected from electric po

Page 28

TROUBLESHOOTING - WFAE-55FS (Solid State Controls) 32 SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Fryer will not heat Unit disconnected from electr

Page 29

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer NOTES 33

Page 30

EXPLODED VIEW: WFAE55F/FS 34 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer WFAE-55F (MANUAL CONTROLS) ELECTRICAL COMPONENTS

Page 31

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer PARTS LIST: WFAE55F/FS 35 WFAE-55F/FS ELECTRIC OPEN FRYPOT CABINET COMPONENT

Page 32 - WARNING: PINCH HAZARD

EXPLODED VIEW: WFAE55F/FS 36 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer WFAE-55F (MANUAL CONTROLS) ELECTRICAL COMPONENTS

Page 33

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer PARTS LIST: WFAE55F/FS 37 WFAE-55F/FS ELECTRIC OPEN FRYPOT ELECTRICAL COMPON

Page 34

FEATURES & OPERATING CONTROLS 2 1 POWER SWITCH (FRYER-OFF-FILTER) FRYER position energizes the FRYER and POWER LIGHT; de-energizes FIL

Page 35

EXPLODED VIEW: WFAE55F/FS 38 WFAE-55FS (SOLID-STATE CONTROLLER) ELECTRICAL COMPONENTS 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electr

Page 36 - EXPLODED VIEW: WFAE55F/FS

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer PARTS LIST: WFAE55F/FS 39 WFAE55F/FS ELECTRIC OPEN FRYPOT ELECTRICAL COMPONE

Page 37 - CABINET COMPONENTS

EXPLODED VIEW: WFAE55F/FS 40 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer WFAE-55F/FS FILTER PUMP COMPONENTS WModel: WFAE

Page 38

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer PARTS LIST: WFAE55F/FS 41 WFAE-55F/FS ELECTRIC OPEN FRYPOT WAND & FILTER

Page 39

EXPLODED VIEW: WFAE55F/FS 42 WFAE-55F/FS AUTO-LIFT COMPONENTS 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer Model: WFAE55F/

Page 40

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer PARTS LIST: WFAE55F/FS 43 WFAE-55F/FS ELECTRIC OPEN FRYPOT AUTO-LIFT COMPONE

Page 41

EXPLODED VIEW: WFAE55F/FS 44 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer WFAE-55F/FS ACCESSORIES & REMOVABLE COMPONEN

Page 42

363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer PARTS LIST: WFAE55F/FS 45 WFAE-55F/FS ELECTRIC OPEN FRYPOT ACCESSORIES &

Page 43

WIRING DIAGRAM 46 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer 342017223118COOKLIGHTHEAT ONLIGHT1840.941.541.524047.247.84

Page 44

WIRING DIAGRAM 47 363 2M-300007 Owners Manual WFAE-50F/FS Free-Standing Electric Fryer 8500W HEATINGELEMENT(2)1L11L11L21L21L31L3112233*18DOWN24RED

Page 45 - AUTO-LIFT COMPONENTS

FEATURES & OPERATING CONTROLS (continued) 3 9 HI-LIMIT THERMOSTAT Provides over-temperature protection by de-energizing HEATING ELEMENTS should

Page 47

DESCRIPTION PART NO. BRUSH, CLEANING HEATING ELEMENT 2P-46479 FLAVOR-SAVER OIL FILTER POWDER (pk45) WS-22410 WAOC-1 MOBILE OIL DISPOSA

Page 48 - WIRING DIAGRAM

WELLS BLOOMFIELD, LLC10 Sunnen Dr., St. Louis, MO 63143telephone: 888-356-5362fax: 314-781-2714www.wells-mfg.com

Page 49

FEATURES & OPERATING CONTROLS 4 Fig. 1 WFAE-55FS Features & Operating Controls BACK VIEWFRONT VIEWLOWER CONTROL PANELRESETHI-LIMITUPPER CONTR

Page 50

FEATURES & OPERATING CONTROLS (continued) 5 WARNING:FIRE HAZARD / HOT OILThe HI-LIMIT THERMOSTAT is a FIRE PROTECTION DEVICE.If tripping persists,

Page 51 - CUSTOMER SERVICE DATA

This appliance is intended for use in commercial establishments only. This appliance is intended to prepare food for human consumption. No other use

Page 52

AGENCY LISTING INFORMATION 7 This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation I

Comments to this Manuals

No comments